Main features:
1. Excellent and fast analysis performance (only 15-30 seconds);
2. Dynamic range: from ppm to%;
3. The open spark stage and special small sample fixtures ensure that the instrument is suitable for analyzing metal samples of various shapes;
4. Precision: better than 1% deviation;
5. Excellent nitrogen element analysis performance;
6. High stability and reliability;
7. Multiple high-performance CCD detector systems can be optionally equipped, with up to 16 CCD detectors according to application requirements, increasing the flexibility of instrument matrix and element analysis upgrades;
8. Calibration of high-level standard samples;
9. PC controlled variable frequency high energy pre spark (HEPS);
10. High precision temperature and pressure control;
11. Advanced software features, easy to operate, and easy to master;
12. Suitable for analyzing various metal materials.
Optical system:
1. Paschen Runge structure, focal length: 500 mm;
2. High performance holographic diffraction grating with 2700 grating lines/mm and 3600 grating lines/mm;
3. 3648 pixels per CCD, with a maximum resolution of 58368 pixels (16 * 3648 pixels);
4. The wavelength of the spectral line: 130-800 nm is determined by the selection of the diffraction grating. The selection of gratings is determined by the manufacturer based on analysis elements and analysis procedures;
5. A sealed vacuum optical chamber can avoid interference from dust and light.
Motivation platform:
1. An open spark stage that can analyze samples of various shapes weighing up to 20Kg;
2. The electrode is easy to disassemble and maintain;
3. Argon gas purging spark table, supporting rapid sample replacement;
4. Adapters for different samples can meet the needs of various samples (optional).
Excitation light source:
1. Fully automatic control of spark source;
2. Semiconductor controlled discharge excitation;
3. Low argon consumption ranging from 1 to 100 A;
4. Convenient use of sample ionization current;
5. The discharge parameters are password protected;
6. Special analysis requirements can have different excitation parameters;
7. Spark light source discharge is stable and not affected by fluctuations in the power supply system;
8. The excitation parameters are calibrated and controlled by the excitation line and analysis program;
9. Spark sources can have multiple parameter settings;
10. Spark frequency: 200 to 1000 Hz (controllable);
11. Spark duration 10-10000 us (controllable).
Spectrometer control system and data readout system:
1. The electronic system has multi-channel integration and data system acquisition functions controlled by a microprocessor;
2. High speed 16 bit analog-to-digital converter;
3. ISP mixed signal Flash microcontroller 100MHz;
4. Multiple connection sources;
5. High speed readout and high-speed USB interface support fast data control and processing system;
6. Up to 16 CCD modules, selected by the manufacturer based on the application situation.
WinLab10 analysis software:
1. Calculate the correction curve for each element taking into account various matrices (reference lines);
2. Intelligence: Standardization can be achieved with a set of standard samples;
3. Easy to operate user graphical interface;
4. Create or modify analysis programs;
5. Commonly used operation function keys;
6. Optional output methods (intensity, intensity ratio, uncorrected concentration, corrected concentration, etc.);
7. Selectable concentration units (ppm,%);
8. Universal standardization;
9. Micro standardization;
10. Correct interference between elements;
11. Automatic standardization;
12. Standard deviation and relative standard deviation functions;
13. Alloy type identification (UNI, ISO, DIN, EN, ASTM, JIS, BS, etc.);
14. Standard sample library;
15. International Standard Material Library;
16. Brand identification;
17. Support the calculation of C equivalent or other parameters;
18. Element analysis results that exceed the range of the working curve can be marked;
19. Equipped with automatic recalibration function based on analysis time or excitation frequency;
20. Statistical function software;
21. Statistical calculations;
22. It can print all excitation results or the average result of up to 100 excitations, as well as their standard deviation and relative standard deviation;
23. The hard disk stores data for future research and analysis, and can be connected to external computers or central systems.
Dimension: L925x W514 x H401 mm;
Weight: approximately 100 Kg;
Power supply: 220V+/-10%, single phase, 50/60 Hz, 10 A, 1.0 KVA.
Note: Shanghai Soohow Honor Optoelectronic Technology Co., Ltd. is a holding subsidiary of Kunshan Soohow Instrument Technology Co., Ltd. The above product content is an official product of Kunshan Soohow Instrument Technology Co., Ltd